Wholesale High Quality Gas Thermal Mass Flow Meter Replace Gas Turbine Flow Meter

Wholesale High Quality Gas Thermal Mass Flow Meter Replace Gas Turbine Flow Meter

Model NO.: DMF-1-Series
Measuring Media: Gas
Measuring Principle: Thermodynamic
Measurement Object: Closed Pipeline
Certification: JIS, DIN, ANS, GB, CE, RoHS, ISO
Trademark: Sincerity
Transport Package: Carton/ Wooden Box Package
Origin: China
HS Code: 9026801000
Please attention: 
BEIJING SINCERITY FACTORY OFFER YOU: 
Wholesale High Quality Gas Thermal Mass Flow Meter Replace Gas Turbine Flow Meter
CertificationWholesale High Quality Gas Thermal Mass Flow Meter Replace Gas Turbine Flow Meter

Kindly reminder: 

all our certifications is REAL ONE. 
NOT FAKE ,NOT FAKE, NOT FAKE !!!

 
PLEASE CONTACT US TO SHOW YOU !!! 

WE HAVE CERTIFICATIONS FOR: 
1. Quality control certifications: ISO 9001/ ISO 4001/ OHSAS 18001 
2. CE Certificate 
3. Explosion Proof Certificate 
4. Certificate of Origin 
5. Production License, and Environmentally Friendly Certificate. 

-------------------------------------------------------------------------------------------------------------------------
WORLD-WIDE CUSTOMERS COMMENTS & FEEDBACK 
Here is some of the comments from our world-wide customers. 
You can check all the comments at our company profile. 
Please visit www. bjsincerity.en.alibaba.com
click "Company profile, then choose "Rating & Reviews"
Then you can see all the comments from our clients.
{Please note: all our cusomter comments is real one, NOT FAKE. }


[TRUST YOU WILL LIKE OUR SERVICES, QUALITY AND PRICE]

Wholesale High Quality Gas Thermal Mass Flow Meter Replace Gas Turbine Flow Meter



Production Description: 
  Insertion Type Segment Type
Measuring media Various gases (except for acetylene gas)       
Range of pipe diameter DN80-6000 mm DN15-2000 mm
Velocity range 0.5-100 Nm/s
Accuracy ±1.0%
Working temperature Sensor: normal temperature type -10ºC to +200ºC, 
high temperature type -10
ºC to +350ºC; 
converter:-20
ºC to +45ºC (for special environment, specify) 
Working pressure Media pressure≤2.5Mpa Media pressure≤4.0Mpa
Power supply Integrated type machine (DC24V or AC220V ≤18W), 
detachable converter (AC220V  ≤19W)
Response speed 1S
Output signal 4-20mA (photoelectric isolation, maximum load 500Ω)
RS-485 (photoelectric isolation)
Pipeline material Carbon steel, stainless steel and plastic, etc.
Display Integrated type: 8-bit field + 24 prompts
Detachable type: 10x2 Chinese characters
Display content Mass flow, volume flow under normal condition, integrated flow, 
standard time and integrated runtime, etc.
Outline of detachable converter Wall-hanging type: 213x185x107mm
Panel-mounting type: 160x80x160mm
Distance between detachable converter and primary instrument ≤25m(primary instrument is powered by detachable converter), 
≤1000m (primary instrument is powered on the site)
Degree of protection of detachable converter Wall-hanging type: IP65
Panel-mounting type: IP52
Degree of protection of primary instrument IP67
Explosive-proof grade of primary instrument ExIICT4
Sensor materials Stainless steels Stainless steel, carbon steels

Upper Limit of the normal usage of gas measurement: 
Model DN(mm) Air N2 (Nitrogen) O2 (Oxygen) H2 (Hydrogen)
DMF-1-980-3 3 2 2 1 0.4
DMF-1-980-6 6 10 10 5 1.6
DMF-1-980-8 8 18 18 9 2.8
DMF-1-980-10 10 28 28 14 4
DMF-1-980-15 15 65 65 32 10
DMF-1-980-25 25 175 175 89 28
DMF-1-980-32 32 290 290 144 45
DMF-1-980-40 40 450 450 226 70
DMF-1-980-50 50 700 700 352 110
DMF-1-980-65 65 1200 1200 600 185
DMF-1-980-80 80 1800 1800 900 280
DMF-1-980-100 100 2800 2800 1420 470
DMF-1-980-125 125 4400 4400 2210 700
DMF-1-980-150 150 6300 6300 3200 940
DMF-1-980-200 200 10000 10000 5650 1880
DMF-1-980-250 250 17000 17000 8830 2820
DMF-1-980-300 300 25000 25000 12720 4060
DMF-1-980-400 400 45000 45000 22608 7200
DMF-1-980-500 500 70000 70000 35325 11280
DMF-1-980-600 600 100000 100000 50638 16300
DMF-1-980-700 700 135000 135000 69240 22100
DMF-1-980-800 800 180000 180000 90432 29000
DMF-1-980-900 900 220000 220000 114500 77807
DMF-1-980-1000 1000 280000 280000 141300 81120
DMF-1-980-1200 1200 400000 400000 203480 91972
DMF-1-980-1500 1500 600000 600000 318000 101520
DMF-1-980-2000 2000 Closed Cooling Tower

Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.

First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.

Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.

Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.arkfluid.com