Shanghai Ito Power Generator Cooling System Usage Notice

Shanghai Ito Power Generator Cooling System Usage Notice

In order to reduce the engine failure caused by improper design of the Ito Power Generating Set, the design of the unit must be designed in accordance with the conditions and precautions of the Ito Generator for the radiator. Radiator usage conditions and precautions are as follows:
First, the use of radiator conditions
1, open use,
(1) The temperature rise of the radiator core group inlet air temperature and ambient temperature ≤ 3 °C;
(2) Inlet and exhaust air area ≥ 120% of radiator ventilation area
2, when using the sound box:
(1) The temperature rise of the radiator core group inlet air temperature and ambient temperature ≤ 10 °C;
(2) The inlet and outlet area of ​​the box is ≥ 110% of the radiator ventilation area;
(3) The minimum wind speed of the air inlet of the box is ≥ 4m/s;
(4) The exhaust resistance of the box is ≤125Pa.
Ito Power Generator Cooling System
Second, the radiator when using the precautions:
1. General precautions when using in open and mute boxes:
(1) When the engine fan and radiator are installed, the fan blade should enter the thickness of 1/2 of the radiator hood to ensure the blowing efficiency;
(2) Anti-freezing and anti-embroidering fluid must be used inside the radiator to prevent the rust inside the engine and the radiator from blocking the cooling core and affecting the cooling efficiency.
(3) Hot air recirculation is not allowed;
2. More attention should be paid to the use of the sound box:
(1) In order to prevent excessive temperature rise in the tank, it is recommended to insulate the exhaust pipe installed in the unit plant with heat, but it is not allowed to perform heat insulation treatment on the exhaust manifold and the supercharger shell;
(2) It should be avoided to install at the front of the outlet of the water tank, keep the air flow passages before and after the cooling core smooth, and reduce the wind resistance as much as possible.

High Carbon Steel Wire Drawing Annealing Line

High and middle and low carbon wire drawing machine line

(I)Wire surface pretreatment line equipment

1. Equipment comprising and technical requirement

(1) Duck billed pay off stand

(2) Mechanical descaler machine

(3) Steel wire ball strong force cleaning up unit:

(4) Electroanalysis pickling

(5) Heating water channel unit:

(6) Boron coating unit:

(7) Drying unit:

2. Main technical parameter

â‘  Steel wire running speed: not less than 1.5m/s

â‘¡ The washing water pressure which is supplied by user: more than 0.2 Mpa

â‘¢ The uninterrupted compression air which is supplied by user: more than 0.6 Mpa.

(II) LZ Straight Line Drawer Set (Group)

1. Equipment comprising

(1) LZ600 straight feeding drawing set (group)

(2) 800 I spool taking-in set

(3) Man-machine interface control contact screen

(4) Whole set of electric console

Specs

(mm)

No. Of

Drafts

Max.

Inlet wire

(mm)

Min.

Outlet wire

(mm)

Motor

Power

(KW)

Max.

Speed

(m/s)

Noise

dB(A)

Φ250

9-12

1.8

0.35

2.2-4

12

80-82

Φ350

6-12

3.5

0.6

7.5-11

20

80-82

Φ400

6-12

4.2

0.75

11-15

20

80-82

Φ450

6-12

4.6

0.85

15-22

18

80-82

Φ500

6-12

5.5

1.0

22-37

18

80-82

Φ560

6-12

6.5

1.3

22-45

18

80-82

Φ600

5-10

7.0

1.8

37-55

16

80-82

Φ700

4-9

8.0

2.4

45-75

12

80-82

Φ800

4-9

10

2.8

55-90

10

80-82

Φ900

4-9

14

3.5

75-132

8

80-82

High Carbon Steel Wire Drawing Annealing Line,Low Carbon Wire Drawing Machine,Wire Drawing Machine,High-Carbon Wire Drawing Machinery